Ullet Nest
Elterwater, Lake District | Deep Retrofit
A deep retrofit, designed around Passivhaus principles, has transformed this once damp, cold and dark house into a warm, comfortable, low energy, light-filled home with significantly improved environmental performance. The works have reduced space-heating demand by an estimated 80% and achieved exceptional airtightness – one of the most overlooked ways to reduce heat loss and energy use – all whilst preserving the character of the original structure.
Space heating demand
-80%
1.2 ACH@50Pa
Final airtightness
ASHP
Samsung air source head pump
-
Floor Area
61 m²
Heating Demand (pre)
523 kWh/m².a
Heating Demand (post)
106 kWh/m².a
Airtightness (pre)
8.7 ACH@50Pa
Airtightness (post)
1.2 ACH@50Pa
Ventilation / Heating
5kW Air source heat pump (Samsung) / dMEV fans with heat recovery (Blauberg)
Windows
Triple glazed timber windows (21 Degrees)
Completion
Summer 2026
-
The client's primary goal was straightforward: a comfortable home with significantly reduced energy consumption. The existing structure offered little in the way of thermal performance, so the design response began with a fabric-first strategy following PassivHaus design principles to optimise the building for an air-source heat pump. Taking the dwelling off its reliance on fluctuating fossil fuel energy prices, while also giving it the capacity to heat the whole home effectively. An early and important decision was the choice of insulation materials. Breathable, natural materials were specified to work with the traditional construction. – Lime and cork based insulating plaster on the walls, and a mixture of wood fibre and hemp insulation products in the roof, were specified to balancing high thermal performance with moisture management appropriate to the existing construction. This approach allowed the team to dramatically improve the building's fabric performance without compromising on the durability of the structure.
-
• Roof: 35mm Gutex Multiplex Top wood fibre insulated sarking board, 200mm Hemp Flax Thermojute Combi Jute between rafters, 50mm Gutex Thermoflex wood fibre insulation in service void. U-value 0.15 W/m²K.
• Walls: Internal wall insulation - 60mm Diasen Diathonite Thermactive lime and cork based insulating plaster. U-value 0.55 W/m²K.
• Floors: Insulated concrete slab (130mm PIR insulation) in lounge area, U-value 0.17 W/m²K, overlay system in kitchen area over existing concrete slab U-value 0.70 W/m²K.
• Windows: Full replacement with triple glazed timber windows from 21 Degrees.
-
Architectural and Low Energy Design / Project Management
SRM Building Design Ltd.
Principal Contractor
Julian Thornton Ltd.
Structural Engineer
Gadsden Consulting Ltd.
ASHP
Roland Hill Ltd.
Airtightness Testing
Green Footsteps
-
The most significant challenge on site was at the foundation level: digging out the existing floors revealed shallow footings at one end of the building, requiring a compromise on the floor construction in the kitchen area.
On site, the most rewarding moments came as the project came together — the transformation from a cold, dark house into a bright, warm, comfortable space, with significantly improved natural light, transforming the feeling of the space.